Submersible Pump Cable

Submersible Pump Cable

Twisted Submersible Pump Cable

Copper

Where To BuySpec Sheet PDF
Applications

May be used within a well casing to supply current to a submersible pump where the cable is not subject to repetitive handling required by frequent pump-unit service. Maximum conductor operating temperature is 75°C at voltages not exceeding 600 volts.

Conductors

Conductors and Grounding Conductor

  • Solid; soft, uncoated copper per ASTM-B3
Insulation

Color-coded PVC (polyvinyl chloride) rated 75°C (Type THW construction)

  • Three-conductor: Black, yellow and red with green ground
  • Two-conductor: Black and red with green ground
Industry Standards

UL: 83
ASTM-B3
NFPA70 (National Electrical Code®)

Assembly

The insulated conductors are twisted together.