APPLICATIONS • For use within the well casing, supplying current to the submersible pump • For use where the cable is not subject to repetitive handling caused by frequent servicing of the pump units • Maximum conductor operating temperature of 75°C at voltages not exceeding 600 volts CONDUCTORS • Solid conductors: Soft, uncoated copper per ASTM B-3 CONDUCTOR INSULATION • Color coded PVC insulated rated 75°C (Type THW construction) • Three conductor: Black, yellow and red with green ground • Two conductor: Black and red with green ground GROUNDING CONDUCTOR • Solid conductor: Soft, uncoated copper per ASTM-B3 ASSEMBLY • The insulated conductors are twisted together INDUSTRY STANDARDS • UL 83 (insulated conductors) • ASTM B-3 • NFPA70: National Electrical Code® SURFACE PRINT • Sample: 12 AWG (UL) THW SUBMERSIBLE PUMP CABLE 600 VOLTS
Flat | PVC Insulation | 600 Volts APPLICATIONS • For use within the well casing, supplying current to the submersible pump. • For use where the cable is not subject to repetitive handling caused by frequent servicing of the pump units. • Maximum conductor operating temperature of 75°C at voltages not exceeding 600 volts. • Minimum operating temperature is -25°C. CONDUCTORS • 7 wire stranded: Soft, uncoated copper per ASTM B-8 ASSEMBLY • The conductors, including the ground wire, are laid parallel and flat and are covered with a yellow PVC insulation rated 75°C (Type THW). The same compound is used to simultaneously form an interconnecting web between the conductors. • One conductor is marked with the surface markings as shown below and sequential footage markings in black. • One conductor is marked with red hash marks. • The grounding conductor is marked with a continuous green stripe with the words “FOR GROUNDING ONLY” included within the stripe. • On three conductor cables with ground, the fourth conductor is unmarked. INDUSTRY STANDARDS • UL 83 • ASTM-B3 and ASTM-B8 • NFPA70: National Electrical Code® SURFACE PRINT • Sample: 12 AWG (UL) THW SUBMERSIBLE PUMP CABLE 600 VOLTS 900 FT
|
|
Product Code
|
AWG Size
|
Number
of Conductors
|
Conductor Stranding
|
Insulation Thickness Mils.
|
Approx. Net Wt. lbs./m ft.
|
|
141-1602
|
12
|
2 w/GRD
|
Solid
|
45
|
95
|
|
141-1603
|
12
|
3 w/GRD
|
Solid
|
45
|
126
|
|
Package Code
|
E
|
|
AWG Size
|
150' coil
|
|
12 Strd 2 w/GRD
|
X
|
|
12 Strd 3 w/GRD
|
X
|
Download PDF
|
Product Code
|
AWG Size
|
Number
of Conductors
|
Conductor Stranding
|
Insulation Thickness Mils.
|
Approx. Shipping Wt. lbs./m ft.
|
Approx. Dimensions Mils.
|
|
141-2602
|
12
|
2 w/GRD
|
7 x .0242
|
45
|
116
|
182 x 558
|
|
141-2603
|
12
|
3 w/GRD
|
7 x .0305
|
45
|
160
|
182 x 746
|
|
141-2803
|
10
|
3 w/GRD
|
7 x .0385
|
45
|
225
|
205 x 770
|
|
Package Code
|
J
|
K
|
|
AWG Size
|
500' spool or reel
|
1000' reel
|
|
12 Strd 2 w/GRD
|
X
|
X
|
|
12 Strd 3 w/GRD
|
X
|
X
|
|
10 Strd 3 w/GRD
|
X
|
X
|
|