APPLICATIONS • May be used as service-entrance conductors when installed asrequired by NEC® Article 230 • May be used for branch circuits or feeders within a building as specified by the NEC® Section 338-10 CONDUCTORS • Stranded conductors: Uncoated copper per ASTM-B3. ASTM-B8 and ASTM-B787 INSULATED CONDUCTORS • Type THHN conductors • Black PVC (polyvinyl chloride), rated 90°C dry or wet, jacketed with black nylon (polyamide) • One of the conductors has a red stripe on the surface of the nylon for polarity identification NEUTRAL CONDUCTOR • Stranded, uncoated copper per ASTM-B3, ASTM-B8, and ASTM-B787 ASSEMBLY • All conductors are laid parallel with the neutral conductor located between the two insulated conductors • The conductors are wrapped with a fiberglass reinforced polyester tape JACKET • A gray, sunlight resistant PVC (polyvinyl chloride) jacket is applied over the complete assembly. INDUSTRY STANDARDS • UL 83 (insulated conductors) • UL 854 Service Entrance Cables, File No. 11098 • ASTM - B3 • ASTM - B8 • ASTM - B787 • Federal Specification A-A- 59544 • NFPA70: National Electrical Code® SURFACE PRINT • Sample: TYPE SE CABLE STYLE U TYPE THHN OR THWN CDRS 2 CDR 6 AWG 1 CDR 8 AWG 600V E11098-A (UL)
|
|
|
Product Code Number
|
2 Conductors
|
Bare Neutral
|
Approx. O.D. Strands
|
Allowable Ampacities*
|
Approx. Net Wt. lbs./m ft
|
|
AWG Size
|
No. of Strands
|
AWG Size
|
No. of Strands
|
60°C **
|
75°C ***
|
90°C ****
|
Dwelling *****
|
|
130-3200
|
8-8
|
7
|
8
|
7
|
400 x 710
|
40
|
50
|
55
|
-
|
241
|
|
130-3400
|
6-6
|
7
|
8
|
7
|
400 x 770
|
55
|
65
|
75
|
-
|
313
|
|
130-3600
|
6-6
|
7
|
6
|
7
|
400 x 790
|
55
|
65
|
75
|
-
|
348
|
|
130-3800
|
4-4
|
7
|
6
|
7
|
400 x 950
|
70
|
85
|
95
|
100
|
486
|
|
130-4000
|
4-4
|
7
|
4
|
7
|
470 x 1030
|
70
|
85
|
95
|
100
|
533
|
|
130-4200
|
3-3
|
7
|
5
|
7
|
500 x 1040
|
85
|
100
|
110
|
110
|
588
|
|
130-4400
|
3-3
|
7
|
3
|
7
|
500 x 1050
|
95
|
115
|
130
|
110
|
647
|
|
130-4600
|
2-2
|
7
|
4
|
7
|
565 x 1100
|
100
|
130
|
150
|
125
|
721
|
|
130-4800
|
2-2
|
7
|
2
|
7
|
565 x 1200
|
100
|
130
|
150
|
125
|
802
|
|
130-6000
|
2/0-2/0
|
19
|
2/0
|
19
|
900 x 1400
|
145
|
175
|
196
|
200
|
1412
|
| * |
Per Table 310-16 NEC® |
| ** |
For termination to equipment for circuits rated 100 amperes or less or marked for 14 AWG through 1 AWG conductors. See Art. 110.14 (C) (1) NEC®. |
| *** |
For termination to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. See Art. 110.14 (C) (1) NEC®. |
| **** |
Dry or wet locations - for derating purposees. |
| ***** |
For dwelling units, conductors shall be permitted at listed ampacities for 120/240 volt, 3 wire, single-phase service conductors that supply the total load. Per Table 310-15 (B)(6) NEC®. |
|
|