APPLICATIONS • 600 volt building wire for use in commercial and industrial applications as specified in the NEC® • 8-1 AWG is marked VW-1 • 1/0 - 750 MCM rated for CT use • 8 AWG -750 MCM in black; Rated sunlight resistant • Pulling lube is not required
CONDUCTORS • Uncoated copper per ASTM-B3, ASTM-B787 (6 AWG-500 MCM), and ASTM-B8 (600 MCM-750 MCM)
INSULATION • Color coded, heat and moisture resistant PVC (polyvinyl chloride)
SLP-JACKET™ • Using Cerro Wire's SLP-JacketTM (Self-Lubricating Polymer) Technology, Cerro Wire SLiPWireTM THHN is self lubricated. • Nylon (polyamide), color coded
INDUSTRY STANDARDS • UL 83 - File No. E15119 • UL 1063 (MTW) - File No. E85964 • AWM - File No. E11829 • Canadian Standard C22.2 No. 75 and CSA Bulletin No. 1451 • ASTM: B3, B8, B787 • WC70/ICEA S-95-658 • Federal Specification A-A-59544 • NFPA70: National Electrical Code®
SURFACE PRINT • Sample: CERRO WIRE VINYLON-A 350 KCMIL (UL) MTW OR THWN-2 OR THHN OR GASOLINE AND OIL RESISTANT II OR AWM FOR CT USE SUNLIGHT RESISTANT 600V-C(UL) TWN75 OR T90 NYLON
|
|
|
Product Code
|
Conductors
|
Covering
|
Approx. O.D. Inches
|
Allowable Ampacities*
|
Approx. Net Wt. lbs./m ft.
|
|
AWG Size
|
No. of Strands
|
PVC Ins. Mils.
|
Nylon jkt. Mils.
|
60°C **
|
75°C ***
|
90°C ****
|
|
112-40XX
|
8
|
19
|
30
|
5
|
0.217
|
40
|
50
|
55
|
63
|
|
112-42XX
|
6
|
19
|
30
|
5
|
0.253
|
55
|
65
|
75
|
96
|
|
112-44XX
|
4 |
19 |
40 |
6 |
0.322 |
70 |
85 |
95 |
153 |
| 112-45XX |
3 |
19 |
40 |
6 |
0.350 |
85 |
100 |
110 |
190 |
|
112-46XX
|
2 |
19 |
40 |
6 |
0.380 |
95 |
115 |
130 |
233 |
|
112-47XX
|
1 |
19 |
50 |
7 |
0.440 |
110 |
130 |
150 |
299 |
|
112-50XX
|
1/0
|
19
|
50
|
7
|
0.480
|
125
|
150
|
170
|
371
|
|
112-52XX
|
2/0
|
19
|
50
|
7
|
0.524
|
145
|
175
|
195
|
459
|
|
112-54XX
|
3/0
|
19
|
50
|
7
|
0.575
|
165
|
200
|
225
|
571
|
|
112-56XX
|
4/0
|
19
|
50
|
7
|
0.630
|
195
|
230
|
260
|
710
|
|
112-60XX
|
250
|
37
|
60
|
8
|
0.700
|
215
|
255
|
290
|
848
|
|
112-64XX
|
300
|
37
|
60
|
8
|
0.750
|
240
|
285
|
320
|
1006
|
|
112-68XX
|
350
|
37
|
60
|
8
|
0.802
|
260
|
310
|
350
|
1166
|
|
112-72XX
|
400
|
37
|
60
|
8
|
0.847
|
280
|
335
|
380
|
1324
|
|
112-80XX
|
500
|
37
|
60
|
8
|
0.930
|
320
|
380
|
430
|
1640
|
|
112-84XX
|
600
|
61
|
70
|
9
|
1.030
|
355
|
420
|
475
|
1988
|
|
112-88XX
|
750
|
61
|
70
|
9
|
1.136
|
400
|
475
|
535
|
2459
|
|
| XX |
Color Add Code (See chart below) |
| * |
Per Table 310-16 NEC® |
| ** |
For termination to equipment for circuits rated 100 amperes or less, or marked Nos. 14 through 1 conductors. Also for MTW used in wet locations or exposed to oil or coolant. |
| *** |
For termination to equipment for circuits rated over 100 amperes or marked for conductors larger than No. 1. Also for THWN-2 exposed to oil or coolant and MTW in dry locations. |
| **** |
For THHN used in dry locations and THWN-2 used in wet or dry locations. |
|
|